The Thorn Thermo couple also known as the thermocoupling, when you start the pilot, you need to manually depress the gas valve for 10 to 20 seconds to give the thermocouple a period to heat up and start generating enough current to keep the gas control valve open. If the pilot won't stay lit no matter how long you depress the gas valve, the thermocouple could be damaged. You can test the thermocouple by disconnecting it from the gas valve and calculating the voltage between your conductors. You should get yourself a reading of around 40 millivolts when the pilot flame is on. A reading of significantly less than 25 millivolts shows that the thermocouple is certainly defective and needs to be changed., Main Thermocouples Can Be Dispatched For Next Day Delivery

Delivery

THORN Boiler Spares orders - delivered within 24 hours for all in-stock THORN spare parts, when purchased before 3pm. We also supply many other spare parts and accessories for THORN boilers.

Disclaimers:

  • Warranty

    THORN spare parts come with manufacturers standard twelve months warranty.

  • Warning

    When replacing any spare part on appliances, use only genuine boiler spare parts that you can be assured conform to the safety and performance specification that the boiler manufacturer recommends. For your safety & your families, please do not use reconditioned or copy parts that have not been clearly authorised by the boiler manufacturer.