IDEAL  000842

IDEAL 000842

Previous Code: 576890051

£21.86ex-vat


IDEAL 000842 THERMOCOUPLE - WLX RS45P

Product Information

Part also fits:

Buy your Ideal 000842 - Wlx Rs45p Thermocouple today, with a fast UK delivery..
The Ideal Wlx Rs45p Thermocouple also known as the thermo coupling, anytime you start the pilot, you will need to manually depress the gas valve for 10 to 20 seconds to give the thermocouple a period to heat up and begin generating enough current to keep the gas control valve open. If the pilot won't stay lit no matter how long you depress the gas valve, the thermocouple could be damaged. You can test the thermocouple by disconnecting it from the gas valve and calculating the voltage between the conductors. You should get a reading of around 40 millivolts when the pilot flame is on. A reading of less than 25 millivolts indicates that the thermocouple is normally defective and neeeds replacing., Ideal Thermocouples Are Available Next Day

Delivery

IDEAL Boiler Spares orders - delivered within 24 hours for all in-stock IDEAL spare parts, when purchased before 3pm. We also supply many other spare parts and accessories for IDEAL boilers.

Disclaimers:

  • Warranty

    IDEAL spare parts come with manufacturers standard twelve months warranty.

  • Warning

    When replacing any spare part on appliances, use only genuine boiler spare parts that you can be assured conform to the safety and performance specification that the boiler manufacturer recommends. For your safety & your families, please do not use reconditioned or copy parts that have not been clearly authorised by the boiler manufacturer.