IDEAL  030032

IDEAL 030032

£28.49ex-vat


IDEAL 030032 THERMOCOUPLE 900MM - HONEYWELL Q309A2754B - MEXICO SUPER 2 CF140P

Product Information

Part also fits:

Buy your Ideal 030032 - Mexico Super 2 Cf140p Thermocouple 900mm - Honeywell Q309a2754b today, with a fast UK delivery..
The Ideal Mexico Super 2 Cf140p Thermocouple also known as the thermo coupling, anytime you start the pilot, you will need to manually depress the gas valve for 10 to 20 seconds to give the thermocouple a period to heat up and begin generating enough current to keep the gas control valve open. If the pilot won't stay lit no matter how long you depress the gas valve, the thermocouple could be broken. You can test the thermocouple by disconnecting it from the gas valve and calculating the voltage between your conductors. You should get yourself a reading of around 40 millivolts when the pilot flame is on. A reading of significantly less than 25 millivolts shows that the thermocouple can be faulty and must be replaced., Ideal Thermocouples Are Available Next Working Day

Delivery

IDEAL Boiler Spares orders - delivered within 24 hours for all in-stock IDEAL spare parts, when purchased before 3pm. We also supply many other spare parts and accessories for IDEAL boilers.

Disclaimers:

  • Warranty

    IDEAL spare parts come with manufacturers standard twelve months warranty.

  • Warning

    When replacing any spare part on appliances, use only genuine boiler spare parts that you can be assured conform to the safety and performance specification that the boiler manufacturer recommends. For your safety & your families, please do not use reconditioned or copy parts that have not been clearly authorised by the boiler manufacturer.