IDEAL  000842

IDEAL 000842

Previous Code: 576890051

£21.86ex-vat


IDEAL 000842 THERMOCOUPLE - CONCORD WRS 445P

Product Information

Part also fits:

Buy your Ideal 000842 - Concord Wrs 445p Thermocouple today, with a fast UK delivery..
The Ideal Concord Wrs 445p Thermo couple also known as the thermocoupling, when you start the pilot, you need to manually depress the gas valve for 10 to 20 seconds to provide the thermocouple a period of time to heat up and start generating enough current to keep the gas valve open. If the pilot won't stay lit regardless of how long you depress the gas valve, the thermocouple could be damaged. You can test the thermocouple by disconnecting it from the gas valve and calculating the voltage between the conductors. You should get a reading of around 40 millivolts when the pilot flame is on. A reading of less than 25 millivolts signifies that the thermocouple is definitely faulty and needs to be swapped., Ideal Thermocouples Can Be Delivered Next Day

Delivery

IDEAL Boiler Spares orders - delivered within 24 hours for all in-stock IDEAL spare parts, when purchased before 3pm. We also supply many other spare parts and accessories for IDEAL boilers.

Disclaimers:

  • Warranty

    IDEAL spare parts come with manufacturers standard twelve months warranty.

  • Warning

    When replacing any spare part on appliances, use only genuine boiler spare parts that you can be assured conform to the safety and performance specification that the boiler manufacturer recommends. For your safety & your families, please do not use reconditioned or copy parts that have not been clearly authorised by the boiler manufacturer.