IDEAL  004058

IDEAL 004058

£19.73ex-vat


IDEAL 004058 THERMOCOUPLE 600MM - (S.I.T.) - COMPACT RS60

Product Information

Part also fits:

Buy your Ideal 004058 - Compact Rs60 Thermocouple 600mm - (s.i.t.) today, with a fast UK delivery..
The Ideal Compact Rs60 Thermo couple also known as the thermocoupling, when you start the pilot, you need to manually depress the gas valve for 10 to 20 seconds to provide the thermocouple a period of time to heat up and begin generating enough current to keep the gas valve open. If the pilot won't stay lit regardless of how long you depress the gas valve, the thermocouple could possibly be broken. You can test the thermocouple by disconnecting it from the gas valve and measuring the voltage between your conductors. You should get yourself a reading of around 40 millivolts when the pilot flame is on. A reading of significantly less than 25 millivolts shows that the thermocouple is certainly defective and needs to be changed., Ideal Thermocouples Are Dispatched Same Day, For Next Day Delivery

Delivery

IDEAL Boiler Spares orders - delivered within 24 hours for all in-stock IDEAL spare parts, when purchased before 3pm. We also supply many other spare parts and accessories for IDEAL boilers.

Disclaimers:

  • Warranty

    IDEAL spare parts come with manufacturers standard twelve months warranty.

  • Warning

    When replacing any spare part on appliances, use only genuine boiler spare parts that you can be assured conform to the safety and performance specification that the boiler manufacturer recommends. For your safety & your families, please do not use reconditioned or copy parts that have not been clearly authorised by the boiler manufacturer.